Difference between revisions of "Simulink Tester Issues"

From T-VEC Wiki
Jump to: navigation, search
(Test Vector Generation Failures)
(Signal Range Management)
Line 44: Line 44:
  
 
===Signal Range Management===
 
===Signal Range Management===
Changes in architectural decomposition may cause a signal name to be removed. For example, if a signal is defined as signal A in scope subsystems x\y\z and subsystem y is removed, then that signal is undefined and is removed from the signal range file (with extension .srf).
+
Changes in architectural decomposition may cause a signal name to be removed. For example, if a signal is defined as signal A in the hierarchical scope of subsystems x\y\z and subsystem y is removed, then that signal is undefined and is removed from the signal range file (with extension .srf).
  
 
The translator creates a backup copy of the signal range file (.srf) each time the translator is run. It creates a log file that details every change to the .srf file. It should be possible to recover from an unexpected change to the .srf file.
 
The translator creates a backup copy of the signal range file (.srf) each time the translator is run. It creates a log file that details every change to the .srf file. It should be possible to recover from an unexpected change to the .srf file.

Revision as of 14:53, 25 February 2007